Skip to end of metadata
Go to start of metadata
You are viewing an old version of this page. View the current version.
Compare with Current
View Page History
« Previous
Version 2
Next »
Number | Item | Description |
1 | LED | Z-Axis over current LED: - Green= OK.
- Red= Unconfigured (see status LED #6). Over current detected on axis.
|
2 | LED | Y-Axis over current LED: - Green=OK.
- Red= Unconfigured (see status LED #6). Over current detected on axis.
|
3 | LED | X-Axis over Current LED: - Green=OK
- Red= Unconfigured (see status LED #6). Over current detected on axis
|
4 | Fuse | 2A, Z-Brake Fuse |
5 | LED Bank | 24V_Main - Illuminated LED indicates the machine is powered.
- Not illuminated indicated the the machine is not powered. (anything else?)
24_MOT - Illuminated LED indicates the motors are powered?
- Not illuminated LED indicates failure to configure board or a fault/E-stop has occurred?
24V/5V LOCAL - Illuminated LED indicates, the board subsystems are powered and board is booted (ready to operate?)
- Not illuminated LED indicates
|
6 | LEDÂ | Status LED: - Is Green when the board is properly configured and no faults have occurred.
- If Status LED does not go green (what are the options? off or green?) after powering up machine, there is likely an issue with the amplifier board, logic board or cable between them.
|
7 | Fuse | Fuse size based on machine model: - 10A FUSE item #S81152095 used on Vertex 261,341,342.
- 30A FUSE item #S81152105 used on Excel 51X 70X, 90X, 130X, 170X, 2500.
|