Check the lights of the probe module and probe head when attaching and triggering touching the touchprobe touch probe carefully with a finger:
The PH6 LED should be on when the TP-200 module is not attached
The PH6 LED should be on when the TP-200 module is attached
Triggering Touching the TP-200 module when InSpec is not set to touchprobe touch probe should:
the PH6 probe head LED should not blink but it will remain on
the TP-200 probe module LED should remain offTriggering Touching the TP-200 module when InSpec is set to touchprobetouch probe:
the PH6 probe head LED should blink off
the TP-200 probe module LED should light up with a brighten by an amount commensurate with the probe force as it is deflected.
More detailed debugging instructions can be found at P2 Touchprobe Touch Probe Check