Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Info

This troubleshooting article applies only to post 2020 machines P2 Machines

If the machine is not operating and the” information light” next to the power button at the rear status panel of the machine and the firmware LED on the logic board flashes with the following eight-bit pattern as described here:

...

This error might occur during initialisation initialization if the machine fails to complete the volume finding routine.

Solution

...

  • Check in MotorScope that the negative encoder limit, the index mark, and the positive limit are detected and in the right places.

  • Check the encoder readhead and make sure that it does not blink red when crossing the index mark.

  • Make sure that the machine cannot be pushed into a space between the encoder limit and the hard stop where the encoder limit cannot be detected.

...