Logic board installation guideline

These instructions apply to Post 2020 Machines

 

A spare logic board (item SC8069331) will include a jumper inside the bag. This jumper should be plugged into the logic board if the board is installed on a Post 2020 Machines Vertex model only.

Vertex Logic Board with Jumper

 

If the logic board is installed on an Excel machine, the jumper should not be installed on the logic board.

Excel Logic Board without Jumper

After replacing the logic board on the machine follow these steps to set up the logic board in Motorscope Access

  1. After replacing the Logic Board turn the machine on and open Motorscope.

  2. Motorscope should open in the Configuration view. Else click on View-Configuration:

     

  3. In the Machine Configurator section, select the machine model from the Machine List drop-down menu.

  4. Type the machine serial number and the rest of the fields will be filled automatically.

  5. Select Temporarily Configure.

 

If the machine works well after replacing the logic board and configuring the machine you should make the configuration permanent by clicking on “Permanently Configure”.

 

Product information is subject to change without prior notice as a result of ongoing technical development