Overcurrent Error
Problem
This troubleshooting article applies only to Post 2020 Machines
If the machine is not operating and the” information light” at the rear status panel of the machine and the firmware LED on the logic board flashes with the following eight-bit pattern as described here:
0001 0011 x-axis
0001 0100 y-axis
0001 0101 z-axis
Where 0 indicates a short pulse which is 1/4 second and 1 indicates a long pulse which is 1 second long.
This error results from the amplifier board reaching its current limit for the axis. This error can occur on all three axis but the debugging procedure is always the same.
Solution
This might be caused by:
Amplifier Board
Motor
Motor Cables
Too Much Drive Friction
Related articles
Product information is subject to change without prior notice as a result of ongoing technical development